Switching between the computers
10 · G&D DL-MUX4
Switching commands
The following commands are provided for switching the channel:
Messages
The KVM switch confirms the successful execution of a command and otherwise
sends a meassage.
Switching via web application
A computer, which is connected to the KVM switch, can be accessed via
Config
Panel web application.
The Advanced functions for KVM switches paragraph of the separate manual for the web
application provides detailed information regarding this function.
Switching via SNMP
How to switch the signal transmission via SNMP:
Use the SNMP management station to set the Managed Object selectedChannel to the
number of the channel to be switched to.
Command Channel
1! 1
2! 2
3! 3
4! 4
<! switch to previous channel
>! switch to next channel
NOTE:
The serial device carries out the command directly after it is sent.
A message (see below) informs the serial device concerning the success or failure
of the switching of channels.
Message Meaning
In[x] All switching to channel [x] successful
E01 invalid channel number (out of range)
E06 channel switching failed
E10 invalid command
E13 invalid value (out of range)